HVAC systems /lab/sbs/ en Design of an Energy and Water Efficient Hotel /lab/sbs/UM-design-energy-and-water-efficient-hotel <span>Design of an Energy and Water Efficient Hotel</span> <span><span>Anonymous (not verified)</span></span> <span><time datetime="2015-01-01T00:00:00-07:00" title="Thursday, January 1, 2015 - 00:00">Thu, 01/01/2015 - 00:00</time> </span> <div> <div class="imageMediaStyle focal_image_wide"> <img loading="lazy" src="/lab/sbs/sites/default/files/styles/focal_image_wide/public/article-thumbnail/grandbeach.jpg?h=e388f564&amp;itok=NSgucNz0" width="1200" height="600" alt="Grandbeach"> </div> </div> <div role="contentinfo" class="container ucb-article-categories" itemprop="about"> <span class="visually-hidden">Categories:</span> <div class="ucb-article-category-icon" aria-hidden="true"> <i class="fa-solid fa-folder-open"></i> </div> <a href="/lab/sbs/taxonomy/term/70"> Research </a> </div> <div role="contentinfo" class="container ucb-article-tags" itemprop="keywords"> <span class="visually-hidden">Tags:</span> <div class="ucb-article-tag-icon" aria-hidden="true"> <i class="fa-solid fa-tags"></i> </div> <a href="/lab/sbs/taxonomy/term/96" hreflang="en">HVAC systems</a> <a href="/lab/sbs/taxonomy/term/239" hreflang="en">High Performance Buildings</a> </div> <div class="ucb-article-content ucb-striped-content"> <div class="container"> <div class="paragraph paragraph--type--article-content paragraph--view-mode--default"> <div class="ucb-article-content-media ucb-article-content-media-above"> <div> <div class="paragraph paragraph--type--media paragraph--view-mode--default"> <div> <div class="imageMediaStyle large_image_style"> <img loading="lazy" src="/lab/sbs/sites/default/files/styles/large_image_style/public/article-image/grandbeach.jpg?itok=zn8fFznd" width="1500" height="1001" alt="Grand beach - the prototype of the design hotel"> </div> </div> </div> </div> </div> <div class="ucb-article-text d-flex align-items-center" itemprop="articleBody"> <div><p class="text-align-center">&nbsp;</p> <p>Located in Tropical climate, buildings in Miami requires cooling around the year. Space conditioning and domestic hot water systems account for 41% of all energy usage in a hotel. To save the energy for space cooling and domestic hot water heating, we proposed a heat recovery system which pre-heats the city water using the waste heat from space cooling. We also proposed to collect, store and process the rain water for non-portable usage. The system is implemented at the Grand Beach Hotel in Miami Beach, FL. This is a joint project with UCI Engineering.</p> <h2>Press Release</h2> <p><a href="http://www.coe.miami.edu/sustainability-research" rel="nofollow">UM&nbsp;COE&nbsp;News "Sustainability Research"</a></p> <h2><strong>Publications</strong></h2> <ul> <li>R. J. Miranda, S. Huang, G. A. Barrios, D. Li, W. Zuo 2015. “<a href="/lab/sbs/node/613/attachment" rel="nofollow">Energy Efficient Design for Hotels in the Tropical Climate Using Modelica.</a>” Proceedings of the 11th International Modelica Conference, pp. 71-78, September 21-23, Versailles, France.</li> </ul> <p class="text-align-center"></p> <p class="text-align-center">Figure SBS lab researcher Rey Miranda is giving a technical tour at the Grand Beach Hotel</p></div> </div> </div> </div> </div> <h2> <div class="paragraph paragraph--type--ucb-related-articles-block paragraph--view-mode--default"> <div>Off</div> </div> </h2> <div>Traditional</div> <div>0</div> <div>On</div> <div>White</div> Thu, 01 Jan 2015 07:00:00 +0000 Anonymous 140 at /lab/sbs Model Predictive Control for Chilled Water Plants /lab/sbs/UM-MPC-chiller-plant <span>Model Predictive Control for Chilled Water Plants</span> <span><span>Anonymous (not verified)</span></span> <span><time datetime="2015-01-01T00:00:00-07:00" title="Thursday, January 1, 2015 - 00:00">Thu, 01/01/2015 - 00:00</time> </span> <div> <div class="imageMediaStyle focal_image_wide"> <img loading="lazy" src="/lab/sbs/sites/default/files/styles/focal_image_wide/public/article-thumbnail/chilled_water_pump.jpg?h=48c8c3ee&amp;itok=aFmwZ0FA" width="1200" height="600" alt="Diagram in Modelica of the CWP control system"> </div> </div> <div role="contentinfo" class="container ucb-article-categories" itemprop="about"> <span class="visually-hidden">Categories:</span> <div class="ucb-article-category-icon" aria-hidden="true"> <i class="fa-solid fa-folder-open"></i> </div> <a href="/lab/sbs/taxonomy/term/70"> Research </a> </div> <div role="contentinfo" class="container ucb-article-tags" itemprop="keywords"> <span class="visually-hidden">Tags:</span> <div class="ucb-article-tag-icon" aria-hidden="true"> <i class="fa-solid fa-tags"></i> </div> <a href="/lab/sbs/taxonomy/term/92" hreflang="en">Control strategy</a> <a href="/lab/sbs/taxonomy/term/96" hreflang="en">HVAC systems</a> <a href="/lab/sbs/taxonomy/term/239" hreflang="en">High Performance Buildings</a> <a href="/lab/sbs/taxonomy/term/94" hreflang="en">Modelica</a> </div> <div class="ucb-article-content ucb-striped-content"> <div class="container"> <div class="paragraph paragraph--type--article-content paragraph--view-mode--default"> <div class="ucb-article-content-media ucb-article-content-media-above"> <div> <div class="paragraph paragraph--type--media paragraph--view-mode--default"> <div> <div class="imageMediaStyle large_image_style"> <img loading="lazy" src="/lab/sbs/sites/default/files/styles/large_image_style/public/article-image/chilled_water_pump.jpg?itok=YzjWXHes" width="1500" height="739" alt="Diagram in Modelica of the CWP control system"> </div> </div> </div> </div> </div> <div class="ucb-article-text d-flex align-items-center" itemprop="articleBody"> <div><p class="text-align-center"></p> <p>Improving the energy efficiency of chilled water plants is important since they account for about 35% the energy consumed by commercial building cooling equipment in the U.S. Model predictive control is a feasible way to enhance the operational efficiency of the chilled water plants. Our research is to develop a Python-based dynamic optimization platform that can perform continuous optimization for various control settings of chilled water plants. By using the Modelica modeling language, we can quickly model a chilled water plant with any system configurations and dynamically simulate its control behavior.</p> <h2>Collaborators</h2> <p>&nbsp;<a href="https://www.lbl.gov/" rel="nofollow">Lawrence Berkeley&nbsp;National Laboratory</a></p> <h2><strong>Publications</strong>:</h2> <h4><strong>Journal articles:</strong></h4> <ul> <li>S. Huang, A. Malara, W. Zuo, M. Sohn 2018. "<a href="/p1de0091ffae/node/186/attachment" rel="nofollow">A Bayesian Network Model for the Optimization of a Chiller Plant’s Condenser Water Set Point</a>."Journal of Building Performance Simulation, 11(1), pp. 36-47.</li> <li>S. Huang, W. Zuo, M. Sohn 2018. "<a href="/p1de0091ffae/node/188/attachment" rel="nofollow">A Bayesian Network Model for Predicting Cooling Load of Commercial Buildings</a>." Building Simulation, 11(1), pp. 87-101.</li> <li>S. Huang, W. Zuo, M. Sohn 2017. "<a href="/p1de0091ffae/node/180/attachment" rel="nofollow">Improved Cooling Tower Control of Legacy Chiller Plants by Optimizing the Condenser Water Set Point</a>." Building and Environment, 111, pp. 33-46.</li> <li>S. Huang, W. Zuo, M. Sohn 2016. "<a href="/p1de0091ffae/node/194/attachment" rel="nofollow">Amelioration of the Cooling Load Based Chiller Sequencing Control</a>." Applied Energy, 168, pp. 204-215.</li> </ul> <p><strong>Conference proceedings:</strong></p> <ul> <li>S. Huang, W. Zuo, M. D. Sohn 2016. “A Bayesian Network Model for Predicting the Cooling Load of Educational Facilities.” Proceedings of the ASHRAE and IBPSA-USA SimBuild 2016: Building Performance Modeling Conference, pp. 1-8, August 8-12, Salt Lake City, UT.</li> <li>S. Huang, M.V. Cavey, R. Sterling, W. Zuo, L. Helsen, A. Giretti, M. Bonvini, Z. O’Neill, M. Wetter, A. Costa, G. Boehme, R. Klein, B. Dong, M. M. Keane 2016. “<a href="/lab/sbs/node/601/attachment" rel="nofollow">IEA Annex 60 Activity 2.3: Model Use During Operation, Approach and Case Studies.</a>” Proceedings of the 12th REHVA World Congress (CLIMA2016), May 22-25, Aalborg, Denmark.</li> <li>S. Huang, W. Zuo, M. D. Sohn 2015. “<a href="/lab/sbs/node/603/attachment" rel="nofollow">A New Method for the Optimal Chiller Sequencing Control.</a>” Proceedings of the 14th Conference of International Building Performance Simulation Association (Building Simulation 2015), pp. 316-323, December 7-9, Hyderabad, India.</li> <li>A. C. L. Malara, S. Huang, W. Zuo, M. D. Sohn, N. Celik 2015. “<a href="/lab/sbs/node/611/attachment" rel="nofollow">Optimal Control of Chiller Plants Using Bayesian Network.</a>” Proceedings of the 14th Conference of International Building Performance Simulation Association (Building Simulation 2015), pp. 449-455, December 7-9, Hyderabad, India.</li> <li>T. Li, G. Shao, W. Zuo, S. Huang 2015. “<a href="/lab/sbs/node/615/attachment" rel="nofollow">Genetic Algorithm for Building Optimization - State-Of-The-Art Survey.</a>” Proceedings of the 9th International Symposium on Heating, Ventilation and Air Conditioning (ISHVAC) and the 3rd International Conference on Building Energy and Environment (COBEE), pp. 205-210, July 12-15, Tianjin, China.</li> <li>S. Huang, W. Zuo 2014. “Optimization of the Water-Cooled Chiller Plant System Operation.” Proceedings of the 2014 ASHRAE/IBPSA-USA Building Simulation Conference, pp. 300-307, September 10-12, Atlanta, GA.</li> </ul></div> </div> </div> </div> </div> <h2> <div class="paragraph paragraph--type--ucb-related-articles-block paragraph--view-mode--default"> <div>Off</div> </div> </h2> <div>Traditional</div> <div>0</div> <div>On</div> <div>White</div> Thu, 01 Jan 2015 07:00:00 +0000 Anonymous 134 at /lab/sbs